Описание

  • 3-stage function
  • Housing G2
  • Coiled connection cable, 5 m
  • Including holder
Switching element
2102 NO + 1 NC
CableThe high quality connection cables (individual screening of the safety contacts) are available coiled. 3-stage functionEnabling function is active only in the second stage (middle position, actuating point). If the pushbutton is released or pushed further (panic function), the enabling is removed (dependent on the wiring, see function sequence). Dimension drawing Dimension drawing 210 Dimension drawingDimension drawing210 Technical dataApprovals Mechanical values and environment
Material
Housing Plastic yellow
Cap Elastomer PAK arm, black
Weight
Net 2,5 kg
Ambient temperature -5 ... 50 °C
Degree of protection IP65
Mechanical life
Position 1-2-1 0,1 x 106
Position 1-2-3-1 0,1 x 106
Switching principle Slow-action contact element
Number of positively driven contacts 1
Number of NO contacts 2
Connection Flying lead
Cable length
coiled 5 m
Electrical connection ratings
Rated conditional short-circuit current 100 A
Utilization category according to EN 60947-5-1
AC-15 2A 230V
DC-13 2A 24V
Short circuit protection according to IEC 60269-1 2A gG
Rated insulation voltage Ui 250 V
Rated impulse withstand voltage Uimp 2,5 kV
Switching voltage
Min. at 10mA 12 V
Switching current
Min. at 24V 1 mA
Degree of contamination (external, according to EN 60947-1) 3
Connecting cable 6x0.34mm?
Switching characteristics 3-stage enabling switch
Other
In compliance with 60947-5-8
Reliability values according to EN ISO 13849-1
Enabling switch
B10D 0,5 x 106
''